Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Braz J Cardiovasc Surg ; 39(2): e20220470, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426709

RESUMO

INTRODUCTION: Goal-directed fluid therapy (GDFT) has been shown to reduce postoperative complications. The feasibility of GDFT in transcatheter aortic valve replacement (TAVR) patients under general anesthesia has not yet been demonstrated. We examined whether GDFT could be applied in patients undergoing TAVR in general anesthesia and its impact on outcomes. METHODS: Forty consecutive TAVR patients in the prospective intervention group with GDFT were compared to 40 retrospective TAVR patients without GDFT. Inclusion criteria were age ≥ 18 years, elective TAVR in general anesthesia, no participation in another interventional study. Exclusion criteria were lack of ability to consent study participation, pregnant or nursing patients, emergency procedures, preinterventional decubitus, tissue and/or extremity ischemia, peripheral arterial occlusive disease grade IV, atrial fibrillation or other severe heart rhythm disorder, necessity of usage of intra-aortic balloon pump. Stroke volume and stroke volume variation were determined with uncalibrated pulse contour analysis and optimized according to a predefined algorithm using 250 ml of hydroxyethyl starch. RESULTS: Stroke volume could be increased by applying GDFT. The intervention group received more colloids and fewer crystalloids than control group. Total volume replacement did not differ. The incidence of overall complications as well as intensive care unit and hospital length of stay were comparable between both groups. GDFT was associated with a reduced incidence of delirium. Duration of anesthesia was shorter in the intervention group. Duration of the interventional procedure did not differ. CONCLUSION: GDFT in the intervention group was associated with a reduced incidence of postinterventional delirium.


Assuntos
Estenose da Valva Aórtica , Delírio , Substituição da Valva Aórtica Transcateter , Humanos , Adolescente , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estudos Prospectivos , Estudos de Viabilidade , Objetivos , Delírio/etiologia , Delírio/cirurgia , Hidratação/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Tempo de Internação
2.
Rev. bras. cir. cardiovasc ; 39(2): e20220470, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535548

RESUMO

ABSTRACT Introduction: Goal-directed fluid therapy (GDFT) has been shown to reduce postoperative complications. The feasibility of GDFT in transcatheter aortic valve replacement (TAVR) patients under general anesthesia has not yet been demonstrated. We examined whether GDFT could be applied in patients undergoing TAVR in general anesthesia and its impact on outcomes. Methods: Forty consecutive TAVR patients in the prospective intervention group with GDFT were compared to 40 retrospective TAVR patients without GDFT. Inclusion criteria were age ≥ 18 years, elective TAVR in general anesthesia, no participation in another interventional study. Exclusion criteria were lack of ability to consent study participation, pregnant or nursing patients, emergency procedures, preinterventional decubitus, tissue and/or extremity ischemia, peripheral arterial occlusive disease grade IV, atrial fibrillation or other severe heart rhythm disorder, necessity of usage of intra-aortic balloon pump. Stroke volume and stroke volume variation were determined with uncalibrated pulse contour analysis and optimized according to a predefined algorithm using 250 ml of hydroxyethyl starch. Results: Stroke volume could be increased by applying GDFT. The intervention group received more colloids and fewer crystalloids than control group. Total volume replacement did not differ. The incidence of overall complications as well as intensive care unit and hospital length of stay were comparable between both groups. GDFT was associated with a reduced incidence of delirium. Duration of anesthesia was shorter in the intervention group. Duration of the interventional procedure did not differ. Conclusion: GDFT in the intervention group was associated with a reduced incidence of postinterventional delirium.

3.
J Cardiovasc Magn Reson ; 25(1): 47, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37574535

RESUMO

BACKGROUND: Parametric mapping sequences in cardiovascular magnetic resonance (CMR) allow for non-invasive myocardial tissue characterization. However quantitative myocardial mapping is still limited by the need for local reference values. Confounders, such as field strength, vendors and sequences, make intersite comparisons challenging. This exploratory study aims to assess whether multi-site studies that control confounding factors provide first insights whether parametric mapping values are within pre-defined tolerance ranges across scanners and sites. METHODS: A cohort of 20 healthy travelling volunteers was prospectively scanned at three sites with a 3 T scanner from the same vendor using the same scanning protocol and acquisition scheme. A Modified Look-Locker inversion recovery sequence (MOLLI) for T1 and a fast low-angle shot sequence (FLASH) for T2 were used. At one site a scan-rescan was performed to assess the intra-scanner reproducibility. All acquired T1- and T2-mappings were analyzed in a core laboratory using the same post-processing approach and software. RESULTS: After exclusion of one volunteer due to an accidentally diagnosed cardiac disease, T1- and T2-maps of 19 volunteers showed no significant differences between the 3 T sites (mean ± SD [95% confidence interval] for global T1 in ms: site I: 1207 ± 32 [1192-1222]; site II: 1207 ± 40 [1184-1225]; site III: 1219 ± 26 [1207-1232]; p = 0.067; for global T2 in ms: site I: 40 ± 2 [39-41]; site II: 40 ± 1 [39-41]; site III 39 ± 2 [39-41]; p = 0.543). CONCLUSION: Parametric mapping results displayed initial hints at a sufficient similarity between sites when confounders, such as field strength, vendor diversity, acquisition schemes and post-processing analysis are harmonized. This finding needs to be confirmed in a powered clinical trial. Trial registration ISRCTN14627679 (retrospectively registered).


Assuntos
Imageamento por Ressonância Magnética , Voluntários , Humanos , Berlim , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Voluntários Saudáveis , Espectroscopia de Ressonância Magnética
4.
Anaesthesiologie ; 72(7): 488-497, 2023 07.
Artigo em Alemão | MEDLINE | ID: mdl-37296345

RESUMO

BACKGROUND: Within a central operating room area, after general anesthesia (GA) patients are at risk of hypoxemia during transport to the postanesthesia care unit (PACU); however, specific risk factors have not been conclusively clarified and uniform recommendations for monitoring vital signs during transport within a central operating room area complex do not exist. The purpose of this retrospective database analysis was to identify risk factors for hypoxemia during this transport and to determine whether the use of transport monitoring (TM) affects the initial value of peripheral venous oxygen saturation (SpO2) in the PACU. MATERIAL AND METHODS: This analysis was performed on a retrospectively extracted dataset of procedures in GA within a central operating room area of a tertiary care hospital from 2015 to 2020. The emergence from GA was conducted in the operating room with subsequent transport to the PACU. The transport distance was between 31 and 72 m. Risk factors for initial hypoxemia in the PACU, defined as peripheral oxygen saturation (SpO2) below 90%, were determined using multivariate analysis. After splitting the dataset into patients without TM (group OM) and with TM (group MM) and propensity score matching, the influence of TM on initial SpO2 and the Aldrete score after arrival in the PACU were examined. RESULTS AND DISCUSSION: From a total of 22,638 complete datasets included in the analysis, 8 risk factors for initial hypoxemia in PACU were identified: age > 65 years, body mass index (BMI) > 30 kg/m2, chronic obstructive pulmonary disease (COPD), intraoperative airway driving pressure (∆p) > 15 mbar and positive endexpiratory pressure (PEEP) > 5 mbar, intraoperative administration of a long-acting opioids, first preoperative SpO2 < 97%, and last SpO2 < 97% measured after emergence from anesthesia before transport. At least 1 risk factor for postoperative hypoxemia was present in 90% of all patients. After propensity score matching, 3362 datasets per group remained for analysis of the influence of TM. Patients transported with TM revealed a higher SpO2 at PACU arrival (MM 97% [94; 99%], OM 96% [94; 99%], p < 0.001). In a subgroup analysis, this difference between groups remained in the presence of one or more risk factors (MM 97% [94; 99%], OM 96% [94; 98%], p < 0.001, n = 6044) but was not detectable in the absence of risk factors for hypoxemia (MM 97% [97; 100%], OM 99% [97; 100%], p < 0.393, n = 680). Furthermore, the goal of an Aldrete score > 8 at PACU arrival was achieved significantly more often in monitored patients (MM 2830 [83%], OM: 2665 [81%], p = 0.004). Critical hypoxemia (SpO2 < 90%) at PACU arrival had an overall low occurrence within propensity matched datasets and showed no difference between groups (MM: 161 [5%], OM 150 [5%], p = 0.755). According to these results, consistent use of TM leads to a higher SpO2 and Aldrete score at PACU arrival, even after a short transport distance within an operating room area. Consequently, it appears to be reasonable to avoid unmonitored transport after general anesthesia, even for short distances.


Assuntos
Hipóxia , Transtornos Respiratórios , Humanos , Idoso , Estudos Retrospectivos , Pontuação de Propensão , Hipóxia/epidemiologia , Transtornos Respiratórios/complicações , Fatores de Risco , Anestesia Geral/efeitos adversos
5.
Sensors (Basel) ; 23(6)2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36992016

RESUMO

BACKGROUND: Non-invasive tracking of beat-to-beat pulse transit time (PTT) via piezoelectric/piezocapacitive sensors (PES/PCS) may expand perioperative hemodynamic monitoring. This study evaluated the ability for PTT via PES/PCS to correlate with systolic, diastolic, and mean invasive blood pressure (SBPIBP, DBPIBP, and MAPIBP, respectively) and to detect SBPIBP fluctuations. METHODS: PES/PCS and IBP measurements were performed in 20 patients undergoing abdominal, urological, and cardiac surgery. A Pearson's correlation analysis (r) between 1/PTT and IBP was performed. The predictive ability of 1/PTT with changes in SBPIBP was determined by area under the curve (reported as AUC, sensitivity, specificity). RESULTS: Significant correlations between 1/PTT and SBPIBP were found for PES (r = 0.64) and PCS (r = 0.55) (p < 0.01), as well as MAPIBP/DBPIBP for PES (r = 0.6/0.55) and PCS (r = 0.5/0.45) (p < 0.05). A 7% decrease in 1/PTTPES predicted a 30% SBPIBP decrease (0.82, 0.76, 0.76), while a 5.6% increase predicted a 30% SBPIBP increase (0.75, 0.7, 0.68). A 6.6% decrease in 1/PTTPCS detected a 30% SBPIBP decrease (0.81, 0.72, 0.8), while a 4.8% 1/PTTPCS increase detected a 30% SBPIBP increase (0.73, 0.64, 0.68). CONCLUSIONS: Non-invasive beat-to-beat PTT via PES/PCS demonstrated significant correlations with IBP and detected significant changes in SBPIBP. Thus, PES/PCS as a novel sensor technology may augment intraoperative hemodynamic monitoring during major surgery.


Assuntos
Pressão Arterial , Monitorização Intraoperatória , Humanos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Análise de Onda de Pulso
6.
Front Cardiovasc Med ; 10: 1071643, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36865891

RESUMO

Objectives: Non-invasive assessment of aortic hemodynamics using four dimensional (4D) flow magnetic resonance imaging (MRI) provides new information on blood flow patterns and wall shear stress (WSS). Aortic valve stenosis (AS) and/or bicuspid aortic valves (BAV) are associated with altered aortic flow patterns and elevated WSS. Aim of this study was to investigate changes in aortic hemodynamics over time in patients with AS and/or BAV with or without aortic valve replacement. Methods: We rescheduled 20 patients for a second 4D flow MRI examination, whose first examination was at least 3 years prior. A total of 7 patients received an aortic valve replacement between baseline and follow up examination (=operated group = OP group). Aortic flow patterns (helicity/vorticity) were assessed using a semi-quantitative grading approach from 0 to 3, flow volumes were evaluated in 9 planes, WSS in 18 and peak velocity in 3 areas. Results: While most patients had vortical and/or helical flow formations within the aorta, there was no significant change over time. Ascending aortic forward flow volumes were significantly lower in the OP group than in the NOP group at baseline (NOP 69.3 mL ± 14.2 mL vs. OP 55.3 mL ± 1.9 mL p = 0.029). WSS in the outer ascending aorta was significantly higher in the OP group than in the NOP group at baseline (NOP 0.6 ± 0.2 N/m2 vs. OP 0.8 ± 0.2 N/m2, p = 0.008). Peak velocity decreased from baseline to follow up in the aortic arch only in the OP group (1.6 ± 0.6 m/s vs. 1.2 ± 0.3 m/s, p = 0.018). Conclusion: Aortic valve replacement influences aortic hemodynamics. The parameters improve after surgery.

8.
Front Cardiovasc Med ; 9: 916922, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35911510

RESUMO

Introduction: Myocarditis-like findings after COVID-19 (coronavirus disease 2019) infection and vaccination were reported by applying cardiovascular magnetic resonance (CMR). These results are very heterogenous and dependent on several factors such as hospital admission or outpatient treatment, timing of CMR, and symptomatic load. This retrospective study aimed to identify differences in myocardial damage in patients with persistent symptoms both after COVID-19 infection and vaccine by applying CMR. Materials and Methods: This study entails a retrospective analysis of consecutive patients referred for CMR between August 2020 and November 2021 with persistent symptoms after COVID-19 infection or vaccination. Patients were compared to healthy controls (HC). All patients underwent a CMR examination in a 1.5-T scanner with a scan protocol including: cine imaging for biventricular function and strain assessment using feature tracking, T2 mapping for the quantification of edema, and T1 mapping for diffuse fibrosis and late gadolinium enhancement (LGE) for the detection and quantification of focal fibrosis. Patients were divided into a subacute COVID-19 (sCov) group with symptoms lasting < 12 weeks, post-COVID-19 (pCov) group with symptoms > 12 weeks, and patients after COVID-19 vaccination (CovVac). Results: A total of 162 patients were recruited of whom 141 were included for analysis. The median age in years (interquartile range (IQR)) of the entire cohort was 45 (37-56) which included 83 women and 58 men. Subgroups were as follows (total patients per subgroup, median age in years (IQR), main gender): 34 sCov, 43 (37-52), 19 women; 63 pCov, 52 (39-58), 43 women; 44 CovVac, 43 (32-56), 23 men; 44 HC (41 (28-52), 24 women). The biventricular function was preserved and revealed no differences between the groups. No active inflammation was detected by T2 mapping. Global T1 values were higher in pCov in comparison with HC (median (IQR) in ms: pCov 1002ms (981-1023) vs. HC 987ms (963-1009; p = 0.005) with other parings revealing no differences. In 49/141 (34.6%) of patients, focal fibrosis was detectable with the majority having a non-ischemic pattern (43/141; 30.4%; patients) with the subgroups after infection having more often a subepicardial pattern compared with CovVac (total (% of group): sCov: 7/34(21%); pCov 13/63(21%); CovVac 2/44(5%); p = 0.04). Conclusion: Patients after COVID-19 infection showed more focal fibrosis in comparison with patients after COVID-19 vaccination without alterations in the biventricular function.

9.
Dtsch Med Wochenschr ; 147(9): 528-537, 2022 04.
Artigo em Alemão | MEDLINE | ID: mdl-35468634

RESUMO

Cardiovascular magnetic resonance (CMR) has become an accepted method for noninvasive imaging in cardiology. As part of a multimodality concept, this method can contribute valuable diagnostic aspects, often even as a first-choice method in a variety of diseases. Currently the availability is still limited, but the increasing time efficiency, technical stability and the growing competence will lead to more guideline-compliant use. The increase of CMR inclusion into guidelines of various societies is mainly based on the unique selling point of CMR, which is noninvasive myocardial tissue differentiation. In addition to efficient ischemia diagnosis, the ability to differentiate active from chronic inflammatory processes as well as the identification of reversible and irreversible damage are some aspects CMR can offer. New developments are sequences which allow for a parametric assessment of myocardial tissue based on T1- and T2-relaxation times. This is especially useful if the exact pathophysiology is unclear, as it is often the case in left ventricular hypertrophy for example. Next to the noninvasive myocardial tissue characterization CMR allows for quantitative hemodynamic assessment of the heart and the related pathologies. Flows as well as gradients can be quantified based on 2D-flow-sequences. New 4D-sequences are aiming to further characterize blood flow in the heart and the great vessels beyond flow volume and gradients. As with any diagnostic method a qualified application is crucial. In recent years, the technique itself has become much more stable and consensus recommendations of the Society for Cardiovascular Magnetic Resonance are available for the main indications, both for the MRI scan procedure and for the evaluation. Appropriate qualifications and certification opportunities are offered both nationally and internationally.


Assuntos
Coração , Imageamento por Ressonância Magnética , Técnicas de Diagnóstico Cardiovascular , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Miocárdio
10.
J Magn Reson Imaging ; 55(1): 211-222, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34173297

RESUMO

BACKGROUND: Implementation of four-dimensional flow magnetic resonance (4D Flow MR) in clinical routine requires awareness of confounders. PURPOSE: To investigate inter-vendor comparability of 4D Flow MR derived aortic hemodynamic parameters, assess scan-rescan repeatability, and intra- and interobserver reproducibility. STUDY TYPE: Prospective multicenter study. POPULATION: Fifteen healthy volunteers (age 24.5 ± 5.3 years, 8 females). FIELD STRENGTH/SEQUENCE: 3 T, vendor-provided and clinically used 4D Flow MR sequences of each site. ASSESSMENT: Forward flow volume, peak velocity, average, and maximum wall shear stress (WSS) were assessed via nine planes (P1-P9) throughout the thoracic aorta by a single observer (AD, 2 years of experience). Inter-vendor comparability as well as scan-rescan, intra- and interobserver reproducibility were examined. STATISTICAL TESTS: Equivalence was tested setting the 95% confidence interval of intraobserver and scan-rescan difference as the limit of clinical acceptable disagreement. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used for scan-rescan reproducibility and intra- and interobserver agreement. A P-value <0.05 was considered statistically significant. ICCs ≥ 0.75 indicated strong correlation (>0.9: excellent, 0.75-0.9: good). RESULTS: Ten volunteers finished the complete study successfully. 4D flow derived hemodynamic parameters between scanners of three different vendors are not equivalent exceeding the equivalence range. P3-P9 differed significantly between all three scanners for forward flow (59.1 ± 13.1 mL vs. 68.1 ± 12.0 mL vs. 55.4 ± 13.1 mL), maximum WSS (1842.0 ± 190.5 mPa vs. 1969.5 ± 398.7 mPa vs. 1500.6 ± 247.2 mPa), average WSS (1400.0 ± 149.3 mPa vs. 1322.6 ± 211.8 mPa vs. 1142.0 ± 198.5 mPa), and peak velocity between scanners I vs. III (114.7 ± 12.6 cm/s vs. 101.3 ± 15.6 cm/s). Overall, the plane location at the sinotubular junction (P1) presented most inter-vendor stability (forward: 78.5 ± 15.1 mL vs. 80.3 ± 15.4 mL vs. 79.5 ± 19.9 mL [P = 0.368]; peak: 126.4 ± 16.7 cm/s vs. 119.7 ± 13.6 cm/s vs. 111.2 ± 22.6 cm/s [P = 0.097]). Scan-rescan reproducibility and intra- and interobserver variability were good to excellent (ICC ≥ 0.8) with best agreement for forward flow (ICC ≥ 0.98). DATA CONCLUSION: The clinical protocol used at three different sites led to differences in hemodynamic parameters assessed by 4D flow. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Hemodinâmica , Imageamento por Ressonância Magnética , Adulto , Humanos , Espectroscopia de Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
11.
J Clin Med ; 10(9)2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34062729

RESUMO

(1) Background: To evaluate time-dependent right ventricular (RV) performance in patients with COVID-19-associated acute respiratory distress syndrome (ARDS) undergoing intensive care (ICU) treatment. (2) Methods: This prospective observational study included 21 ICU patients with COVID-19-associated ARDS in a university hospital in 2020 (first wave). Patients were evaluated by transthoracic echocardiography at an early (EE) and late (LE) stage of disease. Echocardiographic parameters describing RV size and function as well as RV size in correlation to PaO2/FiO2 ratio were assessed in survivors and nonsurvivors. (3) Results: Echocardiographic RV parameters were within normal range and not significantly different between EE and LE. Comparing survivors and nonsurvivors revealed no differences in RV performance at EE. Linear regression analysis did not show a correlation between RV size and PaO2/FiO2 ratio over all measurements. Analysing EE and LE separately showed a significant increase in RV size correlated to a lower PaO2/FiO2 ratio at a later stage of COVID-19 ARDS. (4) Conclusion: The present study reveals neither a severe RV dilatation nor an impairment of systolic RV function during the initial course of COVID-19-associated ARDS. A trend towards an increase in RV size in correlation with ARDS severity in the second week after ICU admission was observed.

12.
J Cardiothorac Vasc Anesth ; 35(6): 1737-1746, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33036889

RESUMO

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) has become an alternative treatment for patients with symptomatic aortic stenosis not eligible for surgical valve replacement due to a high periprocedural risk or comorbidities. However, there are several areas of debate concerning the pre-, intra- and post-procedural management. The standards and management for these topics may vary widely among different institutions and countries in Europe. DESIGN: Structured web-based, anonymized, voluntary survey. SETTING: Distribution of the survey via email among members of the European Association of Cardiothoracic Anaesthesiology working in European centers performing TAVR between September and December 2018. PARTICIPANTS: Physicians. MEASUREMENTS AND MAIN RESULTS: The survey consisted of 25 questions, including inquiries regarding number of TAVR procedures, technical aspects of TAVR, medical specialities present, preoperative evaluation of TAVR candidates, anesthesia regimen, as well as postoperative management. Seventy members participated in the survey. Reporting members mostly performed 151-to-300 TAVR procedures per year. In 90% of the responses, a cardiologist, cardiac surgeon, cardiothoracic anesthesiologist, and perfusionist always were available. Sixty-six percent of the members had a national curriculum for cardiothoracic anesthesia. Among 60% of responders, the decision for TAVR was made preoperatively by an interdisciplinary heart team with a cardiothoracic anesthesiologist, yet in 5 countries an anesthesiologist was not part of the decision-making. General anesthesia was employed in 40% of the responses, monitored anesthesia care in 44%, local anesthesia in 23%, and in 49% all techniques were offered to the patients. In cases of general anesthesia, endotracheal intubation almost always was performed (91%). It was stated that norepinephrine was the vasopressor of choice (63% of centers). Transesophageal echocardiography guiding, whether performed by an anesthesiologist or cardiologist, was used only ≤30%. Postprocedurally, patients were transferred to an intensive care unit by 51.43% of the respondents with a reported nurse-to-patient ratio of 1:2 or 1:3, to a post-anesthesia care unit by 27.14%, to a postoperative recovery room by 11.43%, and to a peripheral ward by 10%. CONCLUSION: The results indicated that requirements and quality indicators (eg, periprocedural anesthetic management, involvement of the anesthesiologist in the heart team, etc) for TAVR procedures as published within the European guideline are largely, yet still not fully implemented in daily routine. In addition, anesthetic TAVR management also is performed heterogeneously throughout Europe.


Assuntos
Anestésicos , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Anestesia Geral , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Europa (Continente) , Humanos , Fatores de Risco , Inquéritos e Questionários , Resultado do Tratamento
14.
Rheumatol Int ; 39(6): 1007-1018, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31006048

RESUMO

Due to maturation of joints, various changes take place, not only in the field of paediatric rheumatology but also in paediatric orthopaedics musculoskeletal ultrasound plays an important role in both the diagnosis and the follow-up of diseases in this field. To differentiate between physiological and pathological findings, the knowledge of reference values of joint structures is indispensable. The objective was to define B-mode ultrasound age- and sex-related reference values for the elbow joint in healthy children and adolescents during maturation. In a cross-sectional, multicentre ultrasound study we examined both sides of the elbow joints of 437 healthy children and adolescents (194 boys/243 girls) being between one and less than 18 years old. The children were classified into six equal age groups and divided according to their gender. We measured the distance between the outer margin of the joint capsule and the bone surface to define the bone-capsule distance (BCD), the thickness of the joint cartilage as well as the thickness of the joint capsule. The bone-capsule junction zone and the shape of the joint capsule were analysed qualitatively. The bone capsule distance and the capsule thickness increased with age. In contrast, the joint cartilage thickness decreased. In most cases the junction zone was peaked. The joint capsule showed mostly a concave shape. Intra- and interobserver reliabilities were good. We propose B-mode ultrasound age- and sex-related reference values for the elbow joint in a large number of healthy children and adolescents for the first time. By applying these standard values to the ultrasound examination of the elbow joint, it may be possible to achieve greater certainty in the diagnosis of pathological processes.


Assuntos
Desenvolvimento do Adolescente , Desenvolvimento Infantil , Articulação do Cotovelo/diagnóstico por imagem , Ultrassonografia , Adolescente , Fatores Etários , Criança , Pré-Escolar , Feminino , Voluntários Saudáveis , Humanos , Lactente , Masculino , Valores de Referência
15.
Klin Padiatr ; 229(5): 293-301, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28837973

RESUMO

Background Defining of gray scale ultrasound standard reference values of the shoulder joint in childhood and adolescence during maturation. PATIENTS: We examined 445 healthy girls and boys between 1 year and 18 years of age. Method A cross-sectional multicentre grey-scale ultrasound study was performed to examine the shoulder joint on both sides. The children were divided according to their gender and were further classified into six age groups, which constituted three-year age ranges, to record anatomical development changes. We measured the capsule-bone distance (BCD) as a representation of the intracapsular cavity, as well as the thickness of the joint capsule and joint cartilage. Values were expressed in mean±standard deviation (SD) and minimum-maximum (min-max). The shape of the joint capsule and capsule-bone junction zone was qualitatively analysed. Results The joint cartilage thickness decreased with increasing age in all joints independently from sex and body side. However, the BCD and the capsule thickness increased with age. There was no intraarticular fluid visible. The joint capsule had a predominantly concave form, whereas the capsule-bone junction was mostly sharp. Discussion This study is the first describing age-related normal values of the intracapsular cavity, joint capsule and cartilage thickness as well as their respective shape in a large cohort of healthy children. Conclusion The findings could be helpful to differentiate between physiological and pathological joint conditions and thereby distinguishing age-related variations from alterations caused by inflammation.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Masculino , Valores de Referência
16.
Pediatr Radiol ; 47(10): 1329-1336, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28547137

RESUMO

BACKGROUND: Musculoskeletal US is a noninvasive imaging method for diagnosing and monitoring inflammatory rheumatic diseases. OBJECTIVES: To develop age- and gender-related arthrosonographic reference intervals for the hip joint of healthy children and adolescents. MATERIALS AND METHODS: In a cross-sectional US study, we examined both hip joints of 445 children and adolescents with an age range of 1 year to 18 years. We measured the distance between the bone surface and the outer margin of the joint capsule to define the bone-capsule distance, the joint capsule and cartilage thickness, and the capsule layer thickness. Reference values were calculated. The shape of the joint capsule and bone-capsule junction zone were analyzed qualitatively. An intraobserver analysis was performed. RESULTS: Bone-capsule distance, capsule thickness and the anterior capsule layer increase with age. In contrast, joint cartilage decreases. The posterior capsule layer exhibited constant thickness across all age groups. The difference between both body sides and gender was collectively less than 0.5 mm. The intraobserver variations were within the calculated reference intervals. The insertion of the capsule to the bone was mostly a peaked one. The capsule shape had a convex or straight configuration in a neutral position and a concave position during outward rotation. The intraobserver analysis revealed good to very good concordance. CONCLUSION: We propose age- and gender-related reference intervals for the bone-capsule distance, joint capsule and cartilage thickness of the hip.


Assuntos
Articulação do Quadril/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Fatores Etários , Cartilagem Articular/diagnóstico por imagem , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Valores de Referência
17.
Rheumatol Int ; 36(11): 1569-1577, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27401002

RESUMO

Musculoskeletal ultrasound (MSUS) is an important tool for evaluating disease activity, therapeutic progress, and remission status of rheumatic diseases in children. Knowledge of age-related normal findings is essential when interpreting pathological findings such as those seen in juvenile idiopathic arthritis. To evaluate normal findings of the knee joint, we recorded age-related stages of musculoskeletal development in the knee of 435 healthy children between 1 and 18 years of age using high-resolution B-mode MSUS. We determined approximate age- and sex-related norms for the suprapatellar recess size, ossified patella size, and distal femoral intercondylar cartilage thickness. In almost all age-groups, over 64 % of children had visible fluid accumulation in the suprapatellar recess. Significant correlations were found between chronological age and the suprapatellar recess size and ossified patella length (p < 0.05). An age-dependent decrease in intercondylar cartilage thickness of the distal femoral epiphysis was found in children between 10 and 18 years of age. High-resolution B-mode MSUS is an excellent tool for assessing joint and skeletal development in children. Our reference data can be used to discriminate better between normal physiological findings and pathological abnormalities.


Assuntos
Bolsa Sinovial/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Joelho/diagnóstico por imagem , Patela/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Criança , Feminino , Voluntários Saudáveis , Humanos , Masculino , Valores de Referência
18.
Circ Cardiovasc Imaging ; 9(3): e004038, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26917824

RESUMO

BACKGROUND: Aortic stenosis (AS) leads to variable stress for the left ventricle (LV) and consequently a broad range of LV remodeling. The aim of this study was to describe blood flow patterns in the ascending aorta of patients with AS and determine their association with remodeling. METHODS AND RESULTS: Thirty-seven patients with AS (14 mild, 8 moderate, 15 severe; age, 63±13 years) and 37 healthy controls (age, 60±10 years) underwent 4-dimensional-flow magnetic resonance imaging. Helical and vortical flow formations and flow eccentricity were assessed in the ascending aorta. Normalized flow displacement from the vessel center and peak systolic wall shear stress in the ascending aorta were quantified. LV remodeling was assessed based on LV mass index and the ratio of LV mass:end-diastolic volume (relative wall mass). Marked helical and vortical flow formation and eccentricity were more prevalent in patients with AS than in healthy subjects, and patients with AS exhibited an asymmetrical and elevated distribution of peak systolic wall shear stress. In AS, aortic orifice area was strongly negatively associated with vortical flow formation (P=0.0274), eccentricity (P=0.0070), and flow displacement (P=0.0021). Bicuspid aortic valve was associated with more intense helical (P=0.0098) and vortical flow formation (P=0.0536), higher flow displacement (P=0.11), and higher peak systolic wall shear stress (P=0.0926). LV mass index and relative wall mass were significantly associated with aortic orifice area (P=0.0611, P=0.0058) and flow displacement (P=0.0058, P=0.0283). CONCLUSIONS: In this pilot study, AS leads to abnormal blood flow pattern and peak systolic wall shear stress in the ascending aorta. In addition to aortic orifice area, normalized flow displacement was significantly associated with LV remodeling.


Assuntos
Aorta/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Função Ventricular Esquerda , Idoso , Estenose da Valva Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Projetos Piloto , Estudos Prospectivos , Fluxo Sanguíneo Regional , Estresse Mecânico , Remodelação Ventricular
19.
Int J Cardiovasc Imaging ; 32(3): 461-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26493195

RESUMO

Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7%, respectively), whereas controls showed central blood flow (88.9%). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.


Assuntos
Aorta/fisiopatologia , Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Imagem de Perfusão/métodos , Projetos Piloto , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Stents , Estresse Mecânico , Resultado do Tratamento
20.
Eur Heart J Cardiovasc Imaging ; 15(3): 235-48, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23913332

RESUMO

Cardiovascular magnetic resonance (CMR) is a versatile non-invasive imaging modality that serves a broad spectrum of indications in clinical cardiology and has proven evidence. Most of the numerous applications are appropriate in patients with previous cardiovascular surgery in the same manner as in non-surgical subjects. However, some specifics have to be considered. This review article is intended to provide information about the application of CMR in adults with previous cardiovascular surgery. In particular, the two main scenarios, i.e. following coronary artery bypass surgery and following heart valve surgery, are highlighted. Furthermore, several pictorial descriptions of other potential indications for CMR after cardiovascular surgery are given.


Assuntos
Ponte de Artéria Coronária/métodos , Implante de Prótese de Valva Cardíaca/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/cirurgia , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...